38
About Your System
E201C
SMI
initialization
failure. Power
cycle AC.
System management
interrupt (SMI)
initialization failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
E201D
Shutdown test
failure. Power
cycle AC.
BIOS shutdown test
failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
E201E
POST memory
test failure.
Check DIMMs.
BIOS POST memory test
failure.
See "Troubleshooting
System Memory" on
page 162.
If the problem persists,
see "Getting Help" on
page 185.
E2020
CPU
configuration
failure. Check
screen
message.
Processor configuration
failure.
Check screen for specific
error messages. See
"Troubleshooting the
Processors" on page 171.
E2021
Incorrect
memory
configuration.
Review User
Guide.
Incorrect memory
configuration.
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 162.
Table 1-2.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 38 Tuesday, June 9, 2009 4:09 PM
Содержание PowerEdge T410
Страница 1: ...Dell PowerEdge T410 Systems Hardware Owner s Manual ...
Страница 60: ...60 About Your System ...
Страница 84: ...84 Installing System Components Figure 3 1 Inside the System 1 3 6 2 13 9 8 7 14 15 12 10 11 5 4 ...
Страница 155: ...Installing System Components 155 ...
Страница 156: ...156 Installing System Components ...
Страница 184: ...182 Jumpers and Connectors Power Distribution Board Connectors 1 J_PWR1 connector 2 J_PWR2 connector 1 2 ...
Страница 186: ...184 Jumpers and Connectors ...
Страница 188: ...186 Getting Help ...
Страница 198: ...196 Glossary ...
Страница 204: ...202 Index ...