26
About Your System
E1211
RAID
Controller
battery
failure.
Check
battery.
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Reseat the RAID battery
connector. See "Installing
the RAID Battery" on
page 147 and
"Troubleshooting System
Cooling Problems" on
page 180.
E1216
3.3V
Regulator
failure.
Reseat PCIe
cards.
3.3V voltage regulator failed. Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 189.
E1219
Disk
Backplane
power
failure.
Check BP
power cable.
Storage backplane voltage
regulator has failed.
Remove and reseat the
backplane. If the problem
persists, see "Getting
Help" on page 203.
E1222
CPU # VCACHE
Regulator
failure.
Contact
support.
Processor voltage regulator
failed.
Reseat the processor(s).
See "Troubleshooting the
Processors" on page 190.
If the problem persists,
see "Getting Help" on
page 203.
E122C
CPU Power
Fault. Power
cycle AC.
A power fault was detected
when powering up the
processor(s).
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E122E
On-board
regulator
failed. Call
support.
One of the on-board voltage
regulators failed.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
Code
Text
Causes
Corrective Actions
book.book Page 26 Wednesday, January 20, 2010 10:20 AM
Содержание PowerEdge R910
Страница 1: ...Dell PowerEdge R910 Hardware Owner s Manual Regulatory Model E06S Series Regulatory Type E06S001 ...
Страница 62: ...62 About Your System ...
Страница 84: ...84 Using the System Setup Program and UEFI Boot Manager ...
Страница 130: ...130 Installing System Components Figure 3 21 Removing and Installing the Panel 1 latch 2 panel 2 1 ...
Страница 172: ...172 Installing System Components ...
Страница 192: ...192 Troubleshooting Your System ...
Страница 204: ...204 Getting Help ...
Страница 210: ...Index 210 ...