Parameters
fcf-mac-address
Enter the MAC address of the FCF to be displayed.
Command Modes
•
EXEC
•
EXEC Privilege
Command History
Version 8.3.12.0
Introduced on the S4810.
Version 8.3.16.0
Introduced on the MXL 10/40GbE Switch IO Module.
Usage
Information
The following describes the
show fip-snooping fcf
command shown in the Example
below.
Field
Description
FCF MAC
MAC address of the FCF.
FCF Interface
Slot/port number of the interface to which the FCF is connected.
VLAN
VLAN ID number the session uses.
FC-MAP
FC-Map value the FCF advertises.
ENode Interface
Slot/ number of the interface connected to the ENode.
FKA_ADV_PERIOD
Time (in milliseconds) during which FIP keep-alive advertisements
transmit.
No of ENodes
Number of ENodes connected to the FCF.
FC-ID
Fibre Channel session ID the FCF assigns.
Example
FTOS# show fip-snooping fcf
FCF MAC FCF Interface VLAN FC-MAP FKA_ADV_PERIOD No. of
Enodes
------- ------------- ---- ------ -------------- -------------
54:7f:ee:37:34:40 Po 22 100 0e:fc:00 4000
2
show fip-snooping sessions
Display information on FIP-snooped sessions on all VLANs or a specified VLAN, including the ENode interface and MAC
address, the FCF interface and MAC address, VLAN ID, FCoE MAC address and FCoE session ID number (FC-ID),
worldwide node name (WWNN) and the worldwide port name (WWPN).
S4810 and MXL Switch
Syntax
show fip-snooping sessions [interface vlan
vlan-id
]
Parameters
vlan-id
Enter the vlan-id of the specified VLAN to be displayed.
631
Содержание Force10 Z9000
Страница 1: ...FTOS Command Line Reference Guide for the Z9000 System FTOS 9 1 0 0 ...
Страница 96: ...96 ...
Страница 194: ...194 ...
Страница 312: ...312 ...
Страница 540: ...540 ...
Страница 546: ...546 ...
Страница 560: ...560 ...
Страница 566: ...566 ...
Страница 590: ...action act UpdateCounter param0 1 0x01 param1 0 0x00 output truncated 590 ...
Страница 624: ...624 ...
Страница 638: ...638 ...
Страница 648: ...648 ...
Страница 659: ...Related Commands show gvrp displays the GVRP configuration 659 ...
Страница 660: ...660 ...
Страница 834: ...834 ...
Страница 854: ...854 ...
Страница 906: ...906 ...
Страница 914: ...914 ...
Страница 976: ...976 ...
Страница 990: ...990 ...
Страница 1006: ...1006 ...
Страница 1008: ...1008 ...
Страница 1026: ...1026 ...
Страница 1145: ...10 211 1 2 Outgoing interface list GigabitEthernet 8 0 1145 ...
Страница 1146: ...1146 ...
Страница 1156: ...1156 ...
Страница 1166: ...1166 ...
Страница 1180: ...1180 ...
Страница 1258: ...1258 ...
Страница 1272: ...1272 ...
Страница 1394: ...1394 ...
Страница 1400: ...1400 ...
Страница 1410: ...1410 ...
Страница 1423: ...To display the type of STP guard Portfast BPDU root or loop guard enabled on a port enter the show spanning tree 0 command 1423 ...
Страница 1424: ...1424 ...
Страница 1444: ...1444 ...
Страница 1456: ...FTOS config interface vlan 40 FTOS conf if vlan tagged TenGi 8 0 FTOS conf if vlan exit FTOS config 1456 ...
Страница 1468: ...Version 8 3 8 0 Introduced on the S4810 1468 ...
Страница 1470: ...1470 ...