BROADCAST ALLMULTI MULTICAST MTU:1500 Metric:1
RX packets:0 errors:0 dropped:0 overruns:0 frame:0
TX packets:0 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:0 (0.0 b) TX bytes:0 (0.0 b)
Interrupt:17
ethMd Link encap:Ethernet HWaddr 00:60:16:5C:8C:AA
BROADCAST ALLMULTI MULTICAST MTU:1500 Metric:1
RX packets:0 errors:0 dropped:0 overruns:0 frame:0
TX packets:0 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:0 (0.0 b) TX bytes:0 (0.0 b)
Interrupt:16
eth1a Link encap:Ethernet HWaddr 00:60:16:52:35:28
inet addr:10.241.173.240 Bcast:10.241.173.255 Mask:
255.255.255.0
inet6 addr: fe80::260:16ff:fe52:3528/64 Scope:Link
UP BROADCAST RUNNING ALLMULTI MULTICAST MTU:9000
Metric:1
RX packets:26978140 errors:0 dropped:3370236 overruns:
0 frame:0
TX packets:1818896 errors:0 dropped:0 overruns:0
carrier:0
collisions:0 txqueuelen:1000
RX bytes:2450123730 (2.2 GiB) TX bytes:642406163
(612.6 MiB)
Interrupt:32 Memory:381c08000000-381c087fffff
eth1b Link encap:Ethernet HWaddr 00:60:16:52:35:29
BROADCAST ALLMULTI MULTICAST MTU:1500 Metric:1
RX packets:0 errors:0 dropped:0 overruns:0 frame:0
TX packets:0 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:0 (0.0 b) TX bytes:0 (0.0 b)
Interrupt:36 Memory:381c07000000-381c077fffff
eth1c Link encap:Ethernet HWaddr 00:60:16:52:35:2A
BROADCAST ALLMULTI MULTICAST MTU:1500 Metric:1
RX packets:0 errors:0 dropped:0 overruns:0 frame:0
TX packets:0 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:0 (0.0 b) TX bytes:0 (0.0 b)
Interrupt:36 Memory:381c06000000-381c067fffff
eth1d Link encap:Ethernet HWaddr 00:60:16:52:35:2B
BROADCAST ALLMULTI MULTICAST MTU:1500 Metric:1
RX packets:0 errors:0 dropped:0 overruns:0 frame:0
TX packets:0 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:0 (0.0 b) TX bytes:0 (0.0 b)
Interrupt:37 Memory:381c05000000-381c057fffff
In this example, the failed cable is on the I/O module in slot 1.
5. Disable the all the network ports on the I/O module with the failed cable.
Run the following commands:
netconfig eth1a down
netconfig eth1b down
netconfig eth1c down
netconfig eth1d down
6. Disconnect the failed cable from the switch.
7. Disconnect the failed cable from the Data Domain system.
8. Connect the new cable to the switch.
Data Domain FRUs
DELL EMC CONFIDENTIAL
Replace a Data Domain Ethernet cable