RS-232 console port access
The RS-232 console port is on the PSU-side of the S4048-ON chassis, as shown.
Figure 27 S4048–ON RS–232 console ports
1. Ethernet management port
2. RS-232 console port
Note
Before starting this procedure, be sure that your PC has a 9-pin serial port and that
you have a terminal emulation program installed and running on the PC. If the serial
port cannot accept a female DB-9 connector, obtain a DB-9 male-to-male adaptor.
Procedure
1. Install the provided RJ-45 connector side of the provided cable into the S4048-
ON console port.
2. Install the DB-9 female side of the provided copper cable into the serial port or
into other data terminal equipment (DTE) server hardware that you intend to
use.
3. Keep the default terminal settings on the console as follows:
l
115200 baud rate—set the MicroUSB console port to 9600 baud rate
l
No parity
l
8 data bits
l
1 stop bit
l
No flow control
Enable Data Domain network ports
Before you begin
The SSH session with the Data Domain system should still be active. Log in again if the
session has been terminated.
Complete the following steps to enable the Data Domain network ports after replacing
the switch chassis.
Procedure
1. Enable the all the network ports on the I/O module that was disabled before.
Dell S4048-ON Switch FRUs
DELL EMC CONFIDENTIAL
96
Integrated Data Protection Appliance (IDPA)
2.1