13. Type
no
The screen displays the following:
Proceed with reload [confirm yes/no]:
14. Type
yes
The system re-loads the switch and the switch now runs with the saved
configuration file. The screen displays an output similar to the following:
Mar 12 23:08:23: %STKUNIT1-M:CP %CHMGR-5-RELOAD: User request
to reload the
chas
sis
syncing disks... done
unmounting file systems...
unmounting /f10/usbflash (/dev/sd0e)...
unmounting /f10/phonehome (tmpfs)...
unmounting /f10/flash (/dev/wd0e)...
unmounting /f10/ConfD/db (mfs:491)...
unmounting /usr/pkg (/dev/wd0i)...
unmounting /boot (/dev/wd0b)...
unmounting /usr (mfs:29)...
unmounting /force10 (mfs:24)...
unmounting /lib (mfs:21)...
unmounting /f10 (mfs:18)...
unmounting /tmp (mfs:9)...
unmounting /kern (kernfs)...
unmounting / (/dev/md0a)... done
rebooting...
15. Disconnect the thumbdrive and cables from the switch.
16. Connect Uplink port(s) to customer switch.
17. Connect Management port to customer management switch.
18. Verify the configuration file was copied successfully by validating the port-
channel is up and has active members as follows:
a. Start the EXEC privilege mode by typing the following command:
enable
b. At the Password prompt, type the password for the admin account.
c. At the prompt, type: show interfaces port-channel.
The port channel will be in the switch config file name ex.: Mot_PO3_RSTP.
The following is an example:
DPappliance-switch#show interfaces port-channel 3
Port-channel 3 is up, line protocol is up
Created by LACP protocol
Description: 10GbeTwinax port channel used for customer
uplink
Hardware address is f4:8e:38:6f:1e:fe, Current address is
f4:8e:38:6f:1e:fe
Interface index is 1258292736
Minimum number of links to bring Port-channel up is 1
Internet address is not set
Mode of IPv4 Address Assignment : NONE
DHCP Client-ID :f48e386f1efe
Dell S4048-ON Switch FRUs
DELL EMC CONFIDENTIAL
Copy the switch configuration file from a USB drive to a switch
91