Data Domain FRUs
Field replacement procedures for the following Data Domain systems and disk shelves
are available from the Generator in Solve Desktop. Appropriate IDPA FRUs will be
carried in the Solutions Generator.
l
Data Domain DD6300 system
l
Data Domain DD6800 system
l
Data Domain DD9300 system
l
Data Domain DD9800 system
l
Data Domain DS60 shelf
l
Data Domain ES30/FS15 shelf
Replace a Data Domain Ethernet cable
Connect to port 38 on the Dell switch. The switch port layout is displayed in
.
Procedure
1. Login to the Avamar with SSH using the Avamar IP address.
2. Stop all Avamar services.
Run the following command:
dpnctl stop all
3. Login to the Data Domain with SSH using the Data Domain IP address.
4. Identify the I/O module slot number where the failed cable connects to the Data
Domain system.
Run the following command:
net show config
ethMa Link encap:Ethernet HWaddr 00:60:16:5C:8C:A9
inet addr:10.241.160.24 Bcast:10.241.160.255 Mask:
255.255.255.0
inet6 addr: 2620:0:170:4140:260:16ff:fe5c:8ca9/64
Scope:Global
inet6 addr: fe80::260:16ff:fe5c:8ca9/64 Scope:Link
UP BROADCAST RUNNING ALLMULTI MULTICAST MTU:1500
Metric:1
RX packets:1208361053 errors:0 dropped:92194 overruns:
0 frame:0
TX packets:1366864848 errors:0 dropped:0 overruns:0
carrier:0
collisions:0 txqueuelen:1000
RX bytes:683470101483 (636.5 GiB) TX bytes:
897875829943 (836.2 GiB)
Interrupt:17
ethMb Link encap:Ethernet HWaddr 00:60:16:5C:8C:A8
BROADCAST ALLMULTI MULTICAST MTU:1500 Metric:1
RX packets:0 errors:0 dropped:0 overruns:0 frame:0
TX packets:0 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:0 (0.0 b) TX bytes:0 (0.0 b)
Interrupt:16