e. Verify the new ESXi host is joined to the vSAN cluster.
Run the following command:
esxcli vsan cluster get
f. From the vSphere Web Client, refresh the vSAN status to verify it displays
as healthy.
Resolve cluster warning messages
Complete the following steps to resolve the warning message.
Procedure
1. Expand the cluster by selecting the triangle.
2. If the Virtual SAN Disk Balance displays a warning message, continue with this
procedure. Contact support to resolve other error or warning messages.
3. Select Virtual SAN Disk Balance.
4. Select Rebalance Disks.
The disk rebalance operation takes approximately three hours to complete.
Complete the procedure
Complete the following steps after the replacement component is installed and
configured.
Procedure
1. Clear VMware Alarms.
a. In the VMware web interface, select each virtual SAN alarm alert from the
Alarms section.
b. Right-click each alarm and select Reset to Green.
2. Clear the disk locator LED by selecting All Action and turn the LED to OFF.
3. Log out of all VMware and Dell interfaces.
4. Disconnect the service computer from the top-of-rack switch.
Update the Install Base
After replacing a Dell server or switch chassis, complete the following steps to update
the Install Base with the serial number of the new hardware.
Procedure
1. In an internet browser, navigate to the Business Services Portal at
emc.force.com/BusinessServices
.
2. Under Post Sales, select Install Base Group.
3. In the Case Subtype list box, select IB Status Change, and click Select.
4. Specify your own contact name, email address, phone number, and theater.
Dell PowerEdge R630 Server FRUs
DELL EMC CONFIDENTIAL
Resolve cluster warning messages
61