Staircase Arb (Option E36150ADVU)
Step 1– Select Arb waveform
Press Arb to access the Arb selection menu. Then select Staircase.
Press Back to return to Arb main menu.
Step 2 – Configure the Staircase Arb
Configure the Staircase Arb accordingly. Refer to the below table for details.
Parameter
Available Key Settings
Description
Arb Type
Voltage or Current
Sets the output Arb type.
Default is Voltage.
Action required:
Press Arb Type to toggle between Volt and Curr.
Volt
Selects voltage as output Arb type.
Curr
Selects current as output Arb type.
Start Setting (I0 or
V0)
minimum to maximum
Sets the setting before the staircase.
End Setting (I1 or
V1)
minimum to maximum
Sets the setting after the staircase.
Delay (t0)
0 – 3600 s
Sets the delay time after the trigger is received but before the staircase starts.
Step time (t1)
0 – 3600 s
Sets the time to complete all staircase steps.
End time (t2)
0 – 3600 s
Sets the time the output remains at the end setting after the staircase completes.
90
Keysight E36150 Series User's Guide