LIST OF AVAILABLE MODELS
75
12
12 LIST OF AVAILABLE MODELS
Model
Controlled
height
(mm)
No.
Beams
Response time
AIC OFF
(msec)
Response time
AIC ON
(msec)
Resolution
(mm)
SG4-14-030-OO-P 300 32 15
20
14
SG4-14-045-OO-P 450 48 17
25
14
SG4-14-060-OO-P 600 64 19
29
14
SG4-14-075-OO-P 750 80 20
34
14
SG4-14-090-OO-P 900 96 22
38
14
SG4-14-105-OO-P 1050 112 24
43
14
SG4-14-120-OO-P 1200 128 26
47
14
SG4-14-135-OO-P 1350 144 27
52
14
SG4-14-150-OO-P 1500 160 29
56
14
SG4-14-165-OO-P 1650 176 31
61
14
SG4-14-180-OO-P 1800 192 33
65
14
SG4-30-030-OO-P 300 16 13
16
30
SG4-30-045-OO-P 450 24 14
18
30
SG4-30-060-OO-P 600 32 15
20
30
SG4-30-075-OO-P 750 40 16
23
30
SG4-30-090-OO-P 900 48 17
25
30
SG4-30-105-OO-P 1050 56 18
27
30
SG4-30-120-OO-P 1200 64 19
29
30
SG4-30-135-OO-P 1350 72 19
32
30
SG4-30-150-OO-P 1500 80 20
34
30
SG4-30-165-OO-P 1650 88 21
36
30
SG4-30-180-OO-P 1800 96 22
38
30
With the following formulas (and referring to the response time reported in the following
tables) the user can calculate the response time of whatever cascade he creates:
AIC OFF
(no code)
Tcascade [msec] = T T T 7,5
AIC ON
(with code)
Tcascade [msec] = Tmaster AIC + Tslave1 AIC + Tslave2 AIC + 7,5
Содержание SG4-14-030-OO-P
Страница 1: ...SG4 EXTENDED Instruction Manual ...
Страница 3: ......
Страница 86: ...SG4 EXTENDED INSTRUCTION MANUAL 78 14 14OUTFIT Angled fixing bracket with threaded pins metallic insert ...
Страница 93: ...ACCESSORIES 85 15 Fixing kit MODEL DESCRIPTION CODE ST DM Kit STAND ALONE 95ASE1940 ...
Страница 105: ...ACCESSORIES 97 15 SG4 EXTENDED BRACCI ATTIVO PASSIVO L SG4 EXTENDED BRACCI ATTIVO PASSIVO T ...
Страница 108: ...www datalogic com ...