FUNCTIONS
65
7
7.12 CODING
The coding function allows the ESPE to remain in normal operation also when an
interference condition with an other ESPE occurs, and in particular when the TX of the first
light curtain radiates in the direction of the RX of the second light curtain.
Obviously, both
light curtains must be configured with two different codes (see also par. 2.2.2).
No code
In this situation, no code is selected and the safety light curtain has to be installed
at a
certain distance from other light curtains with no code, in order to avoid possible
interferences that can lead to a dangerous situation.
If the user has to install the light curtains nearer than the minimum allowed distance he
should take care to install the TX of the first light curtain on the same side of the RX of the
second.
Fig. 59 – No code
Code 1 or Code 2
When the user has to install two light curtains at a distance that is lower than the minimum
distance allowed from homologous devices (and has to have the RXs on the same side), he
has to configure the light curtains with different codes.
The configuration by means of GUI changes the code only on RX side; in order to have the
light curtain correctly working, the user has to configure TX side with the same code by
means of BCM.
Fig. 60 – Code 1 and code 2
Содержание SG4-14-030-OO-P
Страница 1: ...SG4 EXTENDED Instruction Manual ...
Страница 3: ......
Страница 86: ...SG4 EXTENDED INSTRUCTION MANUAL 78 14 14OUTFIT Angled fixing bracket with threaded pins metallic insert ...
Страница 93: ...ACCESSORIES 85 15 Fixing kit MODEL DESCRIPTION CODE ST DM Kit STAND ALONE 95ASE1940 ...
Страница 105: ...ACCESSORIES 97 15 SG4 EXTENDED BRACCI ATTIVO PASSIVO L SG4 EXTENDED BRACCI ATTIVO PASSIVO T ...
Страница 108: ...www datalogic com ...