DIAGNOSTIC
69
8
ESPE
WORKING
MODE
INDICATION
LED CONFIGURATION
Off
On
Blink
Indifferent
SUGGESTED ACTION
FAILURE
INFORMATION
FAILURE ON
OSSDS
Activate RESET line. If error
persists contact Datalogic
Automation Technical
Support
FAILURE ON
MICROPROCESSOR
Activate RESET line. If error
persists contact Datalogic
Automation Technical
Support
FAILURE ON
OPTICS
Activate RESET line. If error
persists contact Datalogic
Automation Technical
Support
FAILURE ON EDM
Check EDM feedback line
and EDM configuration.
Activate RESET line
FAILURE ON
RESTART
Check RESTART line
connection.
Activate RESET line
COMUNICATION
FAILURE
Check cascade connection
and correct mounting of
terminator cap. Activate
RESET line
BCM
CONFIGURATION
FAILURE
Re-operate Basic
Configuration. If error
persists contact Datalogic
Automation Technical
Support
ACM
CONFIGURATION
FAILURE
Re-operate Advanced
Configuration. If error
persists contact Technical
Support Make sure the most
recent version of the GUI
available on
www.datalogic.com is
installed.
CRITICAL FAILURE
Turn ON/OFF ESPE. If error
persists contact Datalogic
Automation Technical
Support
POWER SUPPLY
FAILURE
Check Power Supply
Connection. If error persists
contact Technical Support
A critical failure can’t be re-established with a Reset procedure but it’s necessary to switch-
off and switch-on the light curtain; if the failure persists, please contact the Datalogic
Technical Support.
Содержание SG4-14-030-OO-P
Страница 1: ...SG4 EXTENDED Instruction Manual ...
Страница 3: ......
Страница 86: ...SG4 EXTENDED INSTRUCTION MANUAL 78 14 14OUTFIT Angled fixing bracket with threaded pins metallic insert ...
Страница 93: ...ACCESSORIES 85 15 Fixing kit MODEL DESCRIPTION CODE ST DM Kit STAND ALONE 95ASE1940 ...
Страница 105: ...ACCESSORIES 97 15 SG4 EXTENDED BRACCI ATTIVO PASSIVO L SG4 EXTENDED BRACCI ATTIVO PASSIVO T ...
Страница 108: ...www datalogic com ...