INSTALLATION
17
2
The following table shows the operating distances relating to the number of mirrors used.
Do not use more than three mirrors for each device.
The presence of dust or dirt on the reflecting surface of the mirror causes a drastic
reduction in the range.
2.2.5 Checks after first installation
The control operations to carry-out after the first installation and before machine start-up are
listed hereinafter. The controls must be carried-out by qualified personnel, either directly or
under the strict supervision of the person in charge of machinery Safety.
Check that:
ESPE remains in SAFE state intercepting the beams along the protected area using
the specific test piece (TP-14 or TP-30), following the Fig. 16 scheme.
Fig. 16 – Path of the test piece
number of mirrors
operating distance
(30 mm)
operating distance
(14 mm)
0
20 m
7 m
1
16,5 m
5,1 m
2
13,7 m
4,3 m
3
11,6 m
3,7 m