FUNCTIONS
59
7
BLANKING IN BASIC CONFIGURATION MODE
In basic configuration mode only a reduced set of possible blanking configuration is possible.
BCM Configuration: Fixed Blanking
1 Fixed Blanking Zone
Led 8 ON Green
2 Fixed Blanking Zones
Led 8 OFF
1 Fixed Blanking zone: only 1 zone can be configured as blanking zone
2 Fixed Blanking zones: 2 zones can be configured as blanking zone
BCM Configuration: Floating Blanking
Floating Blanking Disabled
Led 6 ON Green
Led 7 ON Green
Floating Blanking 1 beam (with
partial surveillance)
Led 6 ON Green
Led 7 OFF
Floating Blanking 2 beams (with
partial surveillance)
Led 6 OFF
Led 7 ON Green
Reduced Resolution 4
Led 6 OFF
Led 7 OFF
Floating blanking disabled: no Floating Blanking allowed.
Floating Blanking 1 beam: ESPE stays in NORMAL OPERATION if 1 or 0 beams are intercepted.
Floating Blanking 2 beams: ESPE stays in NORMAL OPERATION if 2 adjacent, 1 or 0 beams are
intercepted.
Reduced Resolution 4: ESPE goes in SAFE state if more than 4 adjacent beams gets intercepted.