FUNCTIONS
61
7
FIXED BLANKING
The panel on the right shows the settings of the active blanking zone (in the example here
below the active blanking zone has a dimension of 3 beams and is 7 beams from the bottom
of the light curtain; no tolerance is set).
FIXED BLANKING WITH INCREASED TOLERANCE (TOP
or BOTTOM
)
The example below shows a setting with fixed blanking with increased tolerance top: over
this zone fixed blanking zones only are allowed; under this zone fixed and total surveillance
blanking zones are allowed.
FLOATING BLANKING WITH TOTAL SURVEILLANCE
Floating objects can move up or down intercepting different beams while moving; the objects
can’t overlap nor change relative positions.
Object must be always present in the protected area and intercept the configured number of
beams with a mandatory fixed tolerance of one beam; that is necessary since a moving
object will always intercept a different number of beams.