SG4 EXTENDED INSTRUCTION MANUAL
30
6
Generic configuration information:
user, date, time ...
Identifies a phisycal ESPE system with
a unique configuration (checksum of
ESPE serial numbers, ESPE hardware,
configuration parameters)
Global ESPE system parameters
Parameters of each cascade unit
Device s.n: 123456789
Device s.n: 123456789
Device s.n: 123456789
Device identification (Serial Number)
Configuration ID (checksum of
configuration parameters)
Fig. 29 – Safety report
6.1
RESET TO FACTORY CONFIGURATION
User can also reset ESPE at factory configuration settings with the following push button
action:
1. press and keep pressed CONFIRM button for at least 9 sec. (but less than 30 sec. otherwise
the light curtin goes in lockout failure)
2. the leds blink for a while, then the light curtain resets
3. after reset the light curtains begins its normal functioning with the factory configuration
N.B.: Factory reset will erase both BCM and ACM configurations.