MECHANICAL MOUNTING
19
3
3 MECHANICAL MOUNTING
The emitting (TX) and receiving (RX) units must be installed with the relevant sensitive
surfaces facing each other. The connectors must be positioned on the same side and the
distance must be included within the operating range of the model used (see chapter 11).
The two units must be positioned the most aligned and parallel possible.
The next step is the fine alignment, as shown in chapter 5.
Outfit angled fixing brackets kit, for units mounting, must be used as described below (Fig.
17).
Adjustable supports for adjusting unit inclinations around the axes are available on request
(see chapter 15).
To mount the angled fixing brackets kit, place the threaded pins metallic insert into the
dedicated side seat of the terminator cap side light curtain closing cap; slide the insert
towards the metallic drawn profile groove. Fix the bracket against the profile by tightening the
M5 hexagonal nuts. It’s possible to slide the bracket group along their dedicated rail and fix it
once again just working on the above mentioned nuts.
Fig. 17 – Fixed brackets mounting procedure
In case of applications with particularly strong vibrations, vibration dampers, together with
mounting brackets, are recommended to reduce the impact of the vibrations.
Fig. 18 – Anti-vibration dampers
The recommended mounting positions according to the light curtain length are shown in Fig.
19 and in the following table.
Содержание SG4-14-030-OO-P
Страница 1: ...SG4 EXTENDED Instruction Manual ...
Страница 3: ......
Страница 86: ...SG4 EXTENDED INSTRUCTION MANUAL 78 14 14OUTFIT Angled fixing bracket with threaded pins metallic insert ...
Страница 93: ...ACCESSORIES 85 15 Fixing kit MODEL DESCRIPTION CODE ST DM Kit STAND ALONE 95ASE1940 ...
Страница 105: ...ACCESSORIES 97 15 SG4 EXTENDED BRACCI ATTIVO PASSIVO L SG4 EXTENDED BRACCI ATTIVO PASSIVO T ...
Страница 108: ...www datalogic com ...