ELECTRICAL CONNECTIONS
23
4
MUTING CONFIGURATION RECEIVER
LINE
LAYOUT
CONNECTION
BEHAVIOUR
OSSD1 / OSSD 2
0V
OSSDs
high level = free path
low level = object detection
OVERRIDE
STATUS
0V
OSSDs
high level = override function active
low level = override function not active
NB: at startup there are fluctuations on this line not
concerning the override activation
MUTING LAMP
24Vdc
LAMP
open collector sinks on muting activation.
MUTING1/MUTING2
active on high level at runtime
EARTH
connect directly to earth
BLANKING CONFIGURATION RECEIVER
LINE
LAYOUT
CONNECTION
BEHAVIOUR
RESET
active on high level in failure lockout
RESTART
active on high level at runtime
ALIGNMENT
active on high level at startup
TEACH IN
active on high level at runtime
TOLERANCE
active on high level at startup
EDM
SEE PAR. 7.4 FOR
CONNECTIONS
must be ossds antivalent at runtime with edm
enabled
OSSD1 / OSSD 2
0V
OSSDs
high level = free path
low level = object detection
BLANKING LAMP
24Vdc
LAMP
open collector sinks on blanking active
EARTH
connect directly to earth
EMITTER
LINE
LAYOUT CONNECTION BEHAVIOUR
TEST
active on high level at runtime
EARTH
connect directly to earth
Содержание SG4-14-030-OO-P
Страница 1: ...SG4 EXTENDED Instruction Manual ...
Страница 3: ......
Страница 86: ...SG4 EXTENDED INSTRUCTION MANUAL 78 14 14OUTFIT Angled fixing bracket with threaded pins metallic insert ...
Страница 93: ...ACCESSORIES 85 15 Fixing kit MODEL DESCRIPTION CODE ST DM Kit STAND ALONE 95ASE1940 ...
Страница 105: ...ACCESSORIES 97 15 SG4 EXTENDED BRACCI ATTIVO PASSIVO L SG4 EXTENDED BRACCI ATTIVO PASSIVO T ...
Страница 108: ...www datalogic com ...