7.7.5 Muting timeout
Muting timeout is a time that defines the maximum duration of muting function; after the
timeout the muting ends.
This time can be set from the user in both BCM and ACM mode.
In BCM mode the user can select a timeout of 10 minutes or infinite; “infinite” means that
muting timeout could never end: if the conditions of muting persist, the muting function still
continues to exist. This is not compliant with the 61496-1 rule and the user is warned about
it.
Fig. 45 – Muting timeout
The user can personalize the timeout from 10 minutes to 1080 minutes (that correspond to
18 hours) with steps of 1 minute; the user can even set infinite timeout. In this case there’s a
warning that alerts the user that this timeout is not IEC 61496-1 compliant.
BCM Configuration: Muting Timeout
10 min
Led 7 ON Green
infinite
Led 7 OFF
ACM Configuration: Muting Timeout
Note: Infinite is not 61496-1 compliant thus the user is warned about it