AccuVision
®
AV6010 Long-Range Camera System Manual
Chapter 5
79
05-AV6010_Setup_R10.doc
Accu-Sort Systems, Inc.
RangeFinder Mounting
Use the RangeFinder Mounting window to make adjustments the orientation,
mounting position and front/back box tracking extensions.
NOTE:
It is recommended that the
AV6010 Install Wizard
be used to set
these parameters the first time. Through a series of setup wizards, you
can ‘teach’ the system key parameters which results in auto calibration.
The RangeFinder Mounting window can be used to adjust the dimensions
as necessary to improve system performance.
Prerequisites:
The
AV6010 Install Wizard
should be downloaded and installed on your
computer.
Use the
RangeFinder Wizard
to auto-calibrate these configuration
settings
.
To set the RangeFinder Mounting configuration:
1. Select
Setup > Mounting > RangeFinder
from the menu tree. Select
the camera position that you want to configure (e.g., front, top, back,
etc.). The window for the selected camera position is displayed.
2. Enter the
Mounting Angles
(roll, pitch and yaw).
3. Enter the
Mounting Position
(along belt, across belt and height).
4. Enter the
RangeFinder Ignore Limits
(left and right).
5. Enter the
RangeFinder Settings
as required by the application.
6. Click
Update
to save any changes.
7. Click
Reset
to return all parameters to the last values saved.
See also: Setup > Mounting > RangeFinder in Appendix B.