AccuVision
®
AV6010 Long-Range Camera System Manual
Appendix B
167
A2-AV6010_User Interface_R10.doc
Accu-Sort Systems, Inc.
Communications > (Camera) > Host Network
Host Network Descriptions
Selection
Definition
Host Network Interface
IP Address
Assignment
(drop-down list)
Set as a Dynamic or Static IP.
Host Network Connection
(Functionality is identical for Host Network Ports 1 through 4.)
TCP/IP Server – The AV6010 will function as the Ethernet server
TCP/IP Client – The AV6010 will function as the Ethernet client
UDP Messaging – The AV6010 message will be in the UDP format
(User Datagram Protocol)
Fast Monitor –The AV6010 will sent a message in the Fast Monitor
format. This is a diagnostic message.
Connection Type
(drop-down list)
None
Standard Message – STX data LF
(qty of data fields are determined on the number of bar codes enabled)
Long Message – STX00000,XXXX,DATA,QQ,YYYLF
STX - Header
00000 – Sequence number
XXXX – Box Length (in tach pulses)
Data – Bar code data
(qty of data fields are determined on the number of bar codes enabled)
QQ – quality of reads
YYY – camera head identifier
LF – Trailer
User Configured – This option provides a configurable menu for the
customer to construct the host message format
Message Format
(drop-down list)
Custom Message – This message is hardcoded by software.
Port Number
Set the port number.
Keep Alive
This is the heartbeat message timer. It defines the timing in
milliseconds on how often the keep alive message should be
transmitted to the host.
Keep Alive
Message
This is the heartbeat message. The AV6010 will send this message to
the host to identify that it is functioning even if product is not moving on
the conveyor.