52
Electrical Installation
AccuVision
®
AV6010 Long-Range Camera Manual
Accu-Sort Systems, Inc.
04-AV6010_Electrical_Installation_R12.doc
General Electrical Installation Guidelines and Precautions
It is important that you follow these general precautions when installing,
setting up, operating, maintaining, troubleshooting or replacing any Accu-
Sort products, parts or related equipment.
As you plan and install your AV6010, be sure to keep the following guidelines
in mind:
Determine the AV6010 is in the proper location as outlined in Chapter 3.
Leave adequate clearances (approximately 8-12 inches [203-305mm])
for wiring.
Route wires carefully to reduce or minimize electrical noise.
When power and communication wiring must cross, make their
intersection perpendicular. Avoid running power and data wiring parallel
to each other. If possible, maintain one of the following separations
between the power and data wiring:
12 inch [300 mm] gap
use steel conduit and 1 inch [25 mm] gap
0.25 inch [6.5 mm] of aluminum.
IMPORTANT:
When planning your installation wiring, remember all power
connections must be quick-disconnect. For PERMANENTLY CONNECTED
EQUIPMENT a readily accessible disconnect device must be incorporated
in the building installation wiring. For PLUGGABLE EQUIPMENT the
socket-outlet must be installed near the equipment and must be easily
accessible.
The IEC power connectors of the AV6010 cameras and RangeFinder
provide the necessary quick-disconnect.
WARNING:
To assure no ESD damage will occur, be sure to observe the
precautions outlined in
Chapter 2, Safety
.
IMPORTANT:
Ground the mounting structure to safety ground (protective
earth ground (PE)). See wiring recommendations for safety ground.