AccuVision
®
AV6010 Long-Range Camera System Manual
Chapter 5
67
05-AV6010_Setup_R10.doc
Accu-Sort Systems, Inc.
Mirror Alignment
Before using any of the camera calibration wizards, you will need to:
Install the folding mirrors
Determine proper mirror angles
Confirm proper mirror alignment for the camera position.
Remove the protective film from the mirror surface.
Prerequisites:
Before you begin, you will need:
Mirror alignment tools (8, 15, and 45-degrees)
5/32” Allen Wrench
The standard mirror angles are as follows:
Camera Position Mirror Orientation (standards)
Front / Back
45-degrees
Top Read
15-degrees *
Side Read
15-degrees *
Bottom Read
15-degrees *
Quadrant
45-degrees
* NOTE:
In some applications the top read, side read and bottom read
camera mirror may be set for 8-degrees.The mounting structure drawings
provided with your application will identify which angle is to be used.
Front / Top / Back Read
Orientation of Mirror to Camera
Side Read / Quadrant
Orientation of Mirror to Camera
AV6010 Camera and Mirror Alignment