AccuVision
®
AV6010 Long-Range Camera System Manual
Chapter 2
23
02-AV6010_Safety_R10.doc
Accu-Sort Systems, Inc.
Electrical Safety
AV6010 Camera must be installed in accordance with Canadian Electrical
Code, Part I, CSA C22.1; CSA C22.2 No. 0; and the National Electrical Code,
NFPA 70. For complete requirements, National Electrical Code, ANSI/NFPA
70, Canadian Electrical Code, Part I, C22.1, or other national standard must
be consulted.
For PERMANENTLY CONNECTED EQUIPMENT/RACK MOUNTED,
incorporate a readily accessible disconnect device in the fixed
wiring.
For PLUGGABLE EQUIPMENT/RACK MOUNTED, install the socket-
outlet near the equipment so it is easily accessible.
Make sure that all personnel who work with the equipment know where
the disconnect switches or circuit breakers are located.
Before performing any type of maintenance, turn off power to the unit and
disconnect the power cord.
Be certain your hands and the floor of your work area are dry before
touching electrical equipment or connecting cords.
Routinely check all power cords, plugs, wiring, and cable connections for
any signs of exposed wire or deteriorating insulation. If you notice any
damage, make arrangements with service personnel to repair or replace
the damaged item immediately.
Electrical Grounding Requirements
Before applying power to any device, ALL components MUST be electrically
grounded. Follow these precautions:
Ensure all AC power outlets have a properly grounded receptacle.
ALL components MUST be properly cabled and grounded with three-
conductor AC power cords.
Use the correct power cord for your country.
Reference specific grounding instructions for each component.
Do not use a two-prong adapter.
Do not cut/remove the round grounding prong from any plug.
Do not use an extension cord to defeat any ground.
Содержание Accu-Sort AccuVision AV6010