200 AV6010 and FAST Monitor
AccuVision
®
AV6010 Long-Range Camera System Manual
Accu-Sort Systems, Inc.
A4-AV6010_and_FAST_Monitor_R10.doc
NOTE:
Jot down the camera’s IP address as shown in the
Static Network
Settings
section of the
Network
window. This IP is required when setting up
the connection to the AV6010 camera in the FAST Monitor User Interface.
4. Add the FAST Monitor server to the next available Host Port in the
Host
Network Connection
section of the
Network
window.
5. Select
Fast Monitor
from the Host Port(n) drop-down list.
6. Type the IP address of the FAST Monitor server in the IP input field.
NOTE:
The default IP for the FAST Monitor server is 192.168.250.1.
If this IP does not work, contact Accu-Sort support at 1-800-BAR-CODE.
7. Type 9899 in the Port # input field.
8. Click
Update
.
For additional information on setting up the FAST Monitor Server to connect
to an AV6010 Tunnel, see the
FAST Monitor User Guide
.