SERVICE
41
MAGNET POWER SUPPLY SYSTEM 8500
4.2.13. Interface specification:
The Driver Interface board has following connection:
- P1: Interface to DCCT Electronics
- P2: Interface to Regulation Module
- P3: Interface to CAMAC / IGOR and Customer Modules
- P4: Interface to Io & Vo Read back and Customer modules
- P5: MPS internal Interlocks
- P6: Load Interlocks
- P7: MPS Internal Interlocks
- P8: Main power ON & Reverse polarity outputs
- P9: ON and Polarity status
- P10: Power supplies input
- P11: ±15V and 24V supplies
- P12: Four LED status outputs
- P13: Remote serial lines RS422/RS232
- P14: Local serial lines RS422
- P15: Serial lines power supply outputs
- P16: Four optional non galvanically isolated inputs
- P17: Local RS232 Service connector (not mounted)
- P18: Remote RS234 Service connector (not mounted)
- P19: Optional 10bit Analog input -AD15-
- P20: Optional SPI interfaces
- P21: Water Flow sensor interface
- P22: I2C Port (not used)
- P23: Interface to 16(18)bit ADC
- P24: 3 Optional isolated inputs
- P25: External Interfaces piggy module connector 1
- P26: External Interfaces piggy module connector 2
- P27: Optional isolated output
- P28: Analog input for Tesla measurements -AD1-
- P29: Optional Analog input 12 bit plus sign -AD14-
- P30: Not used
- P31: Not Used
- P32: Reference temperature controller
- P33: Ramp profile synchronization
- P34: External power supply for ±15V DCCT. (Remove ST23 & ST24)
- P35: Not Used
DANFYSIK A/S - DK 2630 TAASTRUP - DENMARK.
DOC NO P80303Sk