MAGNET POWER SUPPLY SYSTEM 8500
3.3.4.4. SW limits.
The limits of the “Arbitrary point method” ramp profile SW are:
-
The set value must be given in ppm. Units
-
The time between two points can be between 0.2 to 65535 seconds.
-
Maximum numbers of stacks: = 15
-
Maximum number of lines in a stack: = 15
The limits of the “Equal time slot method” ramp profile SW are:
-
The set value must be given in a floating point representation normalized to 1.000000.
-
The time slot may be between 0.0125 to 1 second given in a floating point representation
normalized to 1.0000.
-
Maximum numbers of stacks = 1
-
Maximum number of time slots in a stack = 1000
The limits of the “Auto Slew Rate method” ramp profile SW are:
-
Maximum positive slew rate time = 10 sec,
-
Maximum negative slew rate time = 10 sec,
-
Minimum positive slew rate time = 5m sec,
-
Minimum negative slew rate time = 5m sec,
-
Number of points = 80 with a minimum interval of 1.25ms