SERVICE
14
MAGNET POWER SUPPLY SYSTEM 8500
POLARITY DELAY TIME SETUP.
From SW version SCS108
A time delay can be inserted between the OFF state and the activation of the polarity change over
switch. The range of the time delay can be set from 0 to 25.5 seconds, this for letting the rest energy
in the magnet to decay.
The time delay is only inserted, if the power supply was ON before invoking the POL +/- command.
That is, when just changing the polarity in the power OFF mode, no time delay will be inserted.
Parameters
Default setting after “COLD BOOT”
No polarity delay.
DANFYSIK A/S - DK 2630 TAASTRUP - DENMARK.
DOC NO P80303Sk