MAGNET POWER SUPPLY SYSTEM 8500
3.3.6.
SW Commands.
Following are the commands for the standard software listed in alphabetic order.
Please see the SW appendix for detail explanation of every command.
STANDARD COMMANDS. summary
AD X
.
. . Read value from an ADC chan-
nel.
ADR
.
. . Read the address of the MPS.
ADR XXX . . Write an address to a MPS.
ASW
.
. . Enters answer mode.
CLOCK.
. . Reads the current time
CLOCK
. . HH,MM,SS,DD,MM,YYYY
Sets the clock.
CMD
.
. . Read current control mode.
CMDSTATE . Read current control state.
DA x,xxxxxx . Writes a value xxxxxx to a Digital
to Analog converter x. (Alternative
W(x) or WA command.)
DA 0,xxxxxx,y Writes a value xxxxxx to the
Digital to Analog converter 0,
which is used for the current
setting, through HW register 0 or 1
given by the value y.
ERRC .
. . Coded error message.
ERRT .
. . Text string error message.
F
.
.
. . Main Power OFF.
F1 .
.
. . Auxiliary-1 output line OFF.
“F2"
.
. . Auxiliary-2 output line OFF.
GOFF .
. . Global OFF
Same as N1 command
IEEE
.
. . Used to set IEEE interface com-
munication if present
LALL .
. . Listen ALL.
LOC
.
. . Change to Local Control.
LOCK .
. . Lock the MPS in Local Control.
N
.
.
. . Main Power ON.
N1 .
.
. . Auxiliary-1 output line ON.
“N2"
.
. . Auxiliary-2 output line ON.
NASW .
. . No answer mode.
NERR .
. . No error message.
PO
.
. . Polarity status.
PO +/- .
. . Change to Normal polarity.
PRINT .
. . Reads internal user information
about the MPS
R(x).
.
. . Read slew DAC 1 or 2
R3 .
.
. . Read slew DAC 1 absolute
RA .
.
. . Read the set value.
(Preferred new command:
“DA 0")
REM
.
. . Change to remote control.
RLOCK
. . Remote line only
RS
.
. . Reset interlocks.
S1
.
. . Read the internal status.
S1H
.
. . Read internal status in HEX
format
S3
.
. . Read the internal extended status.
S3H
.
. . Read internal extended status in
HEX format
S1FIRST.
. . Read the interlock first catch sta-
tus.
SFIRSTH. . . Read the interlock first catch sta-
tus in HEX format
S1TIME.
. . Read the time when the first inter-
lock occurred..
SOFF
.
. . Slow OFF
Off command followed by an
WA 000000
TD
.
. . Test DAC function
TYPE .
. . AD type in use
UNLOCK . . Unlock the MPS
VER.
.
. . Reads the software version
W(x)
.
. . Write slew DAC 1 or 2
W3
.
. . Write slew DAC 1 absolute
WA
XXXXXX
. Write a set value (Set output cur-
rent). (Preferred new
command: “DA 0,xxxxxx”)
X is a number from 0 to 9 and Commands in quotation marks are optional.