Programmable SyncPos motion controller
MG.10.J8.02 – VLT is a registered Danfoss trade mark
190
45
I_R EFSWITCH
I_REFSWITCH determines which input of the option
card should serve as reference switch. It is possible
to react to a positive or negative edge, using a
positive or negative number.....
Behavior after reaching see HOMETYPE (40).
Content
Input reference switch
Parameter Group
Axis parameter Inputs/Outputs AXI
CAM-Editor: index card Inp/Outp
Value range
1 … 8
= Reaction to a positive edge on
input 1 … 8
0
= no function
★
0
–1 … –8
= Reaction to a negative edge
on input 1 … 8
46
I_POSLIMITSW
I_POSLIMITSW determines which input should be
interpreted as the positive limit switch.
It is possible to react to a positive or negative edge,
using a positive or negative number.....
Content
Positive limit switch
Parameter Group
Axis parameter Inputs/Outputs AXI
CAM-Editor: index card Inp/Outp
Value range
1 … 8
= Reaction to a positive edge
on input 1 … 8
0
= no function
★
0
–1 … –8
= Reaction to a negative edge
on input 1 … 8
47
I_N EG LIMITSW
I_NEGLIMITSW determines which input should be
interpreted as the negative limit switch.
It is possible to react to a positive or negative edge,
using a positive or negative number.....
Content
Negative limit switch
Parameter Group
Axis parameter Inputs/Outputs AXI
CAM-Editor: index card Inp/Outp
Value range
1 … 8
= Reaction to a positive edge
on input 1 … 8
0
= no function
★
0
–1 … –8
= Reaction to a negative edge
on input 1 … 8
Parameter Reference