Programmable SyncPos motion controller
MG.10.J8.02 – VLT is a registered Danfoss trade mark
168
VLT par. #
Option parameter
Parameter Read/Write
LCP access
# and name
Application program
700
—
GETVLT/SETVLT parameter number
Ex.: var = GETVLT 700
701
102
PRGPAR
702
11
KPROP
703
12
KDER
704
13
KI NT
GET/SET parameter name
705
21
KILIM
Ex.: var = GET KPROP
706
35
BANDWIDTH
707
36
FFVEL
708
37
FFACC
709
65
SYNCVFTI ME
710-779
130 – 229
GET/SET parameter number
Ex.: var = GET 131
780
–
GETVLT/SETVLT parameter number
781
–
Program ID
Ex.: var = GETVLT 780
795-799
130 – 229
GET/SET parameter number
Ex.: var = GET 132
Group 7:
NB!
In general it is very important to optimize the
VLT parameters to the motor, i.e. by using
AMA, in order to obtain a good control behavior.
Parameter 205
Parameter 205, maximum reference must be set in
accordance with maximum velocity (option para-
meter #1) before the controller parameters are
optimized.
Parameter Reference