Programmable SyncPos motion controller
MG.10.J8.02 – VLT is a registered Danfoss trade mark
172
Parameter Code
Parameter Name
VLT- SyncPos
Par.
Unit
Factory
No.
Par.No.
Group
Setting
KINT
Integral value for PID control
704
13
AXR
–
0
K P ROP
Proportional value for PID control
702
11
AXR
–
30
MENCODER
Resolution of the encoder 1 (master)
30
AXE
counts/rev.
500
MENCODERTYPE
Encoder type for encoder 0 (Master)
67
AXE
–
0
N E G L I M IT
Negative software limit switch
4
AXI
q c
–500000
O_AXMOVE
Output for motion command active
64
AXI
–
0
O_B RAKE
Output for mechanical brake
48
AXI
–
0
O_E R RO R
Output for error
108
G LS
–
0
POSDRCT
Rotational direction
28
AXE
–
1
PO SE R R
Maximum tolerated position error
15
AXR
q c
20000
POSFACT_N
Denominator user factor
26
AXE
–
1000
POSFACT_Z
Numerator user factor
23
AXE
–
1000
POS LI M IT
Positive software limit switch
5
AXI
q c
500000
PRGPAR
Activated program number
701
102
G LS
–
– 1
PROFTIME
Scan time for profile generator
29
AXE
msec
1000
RAMPMIN
Shortest ramp
31
AXV
msec
1000
RAM PTYP E
Ramp type
32
AXV
0
R E GWMAX
Size of the control window (activation)
38
AXR
q c
0
R E GWM I N
Size of the control window (deactivation)
39
AXR
q c
0
R EVE RS
Reverse behavior for slave
63
AXR
–
0
SWN E G LI MACT
Negative software limit switch active
19
AXI
–
0
SWPO SLI MACT
Positive software limit switch active
20
AXI
–
0
SYNCACCURACY Size of the precision window for position synchronization 55
AXS
q c
1000
SYNCFACTM
Synchronization factor master (M:S)
49
AXS
q c
1
SYNCFACTS
Synchronization factor slave (M:S)
50
AXS
q c
1
SYNCFAULT
Marker number for fault
57
AXS
–
10
SYN CMAR KM
Marker number for master
52
AXS
–
1
SYNCMARKS
Marker number for slave
53
AXS
–
1
SYNCMFTIM E
Defines filter time for marker correction
18
AXS
msec
0
SYNCMFPAR
Marker filter configuration
17
AXS
–
0
SYNCMMAXCORR Limits max. correction done by marker correction
6
AXS
qc
0
SYNCMPULSM
Marker interval for master
58
AXS
qc
500
SYN CM P U LS S
Marker interval for slave
59
AXS
q c
500
SYNCMSTART
Start behavior for marker synchronization
62
AXS
–
0
SYNCMTYPM
Marker type for master
60
AXS
–
0
SYNCMTYPS
Marker type for slave
61
AXS
–
0
SYN CMWI N M
Tolerance window for master marker monitoring
68
AXS
q c
0
SYNCMWINS
Tolerance window for lave marker monitoring
69
AXS
qc
0
SYNCOFFTIME
Compensation velocity of an offset
16
AXS
msec
0
SYNCPOSOFFS
Position offset for positioning synchronization
54
AXS
qc
0
SYNCREADY
Marker number for ready
56
AXS
–
1
SYNCTYPE
Type of synchronization: normal or with look ahead
51
AXS
–
0
SYNCVELRE L
Tolerated deviance of the slave drive
from the master velocity in %
66
AXS
%
0
SYNCVFTI ME
Velocity filter
709
65
AXS
τ
_filt (
µ
sec)
0
TESTTI M
Time in target window
24
AXI
ms
0
TESTVAL
Limit value for reading in target window
25
AXI
q c
1
TESTWI N
Size of target window
8
AXI
q c
0
T I M E R
Sampling time for PID control
14
AXR
msec
1
VE LMAX
Maximum velocity
1
AXV
Rpm
3000
VELMAXQC
Maximum velocity (internal parameter)
9
AXV
qc/ms *
1/65536
VELRES
Velocity resolution
22
AXV
100
Parameter Reference