13-52 SL Controller Action
Array [20]
Option:
Function:
commands coming from either the digital
inputs or via a fieldbus.
[16] Select preset ref
6
Selects preset reference 6.
If the active preset reference is changed,
it will merge with other preset reference
commands coming from either the digital
inputs or via a fieldbus.
[17] Select preset ref
7
Selects preset reference 7.
If the active preset reference is changed,
it will merge with other preset reference
commands coming from either the digital
inputs or via a fieldbus.
[18] Select ramp 1
Selects ramp 1.
[19] Select ramp 2
Selects ramp 2.
[20] Select ramp 3
Selects ramp 3.
[21] Select ramp 4
Selects ramp 4.
[22] Run
Issues a start command to the frequency
converter.
[23] Run reverse
Issues a start reverse command to the
frequency converter.
[24] Stop
Issues a stop command to the frequency
converter.
[25] Qstop
Issues a quick stop command to the
frequency converter.
[26] Dcstop
Issues a DC stop command to the
frequency converter.
[27] Coast
The frequency converter coasts
immediately. All stop commands
including the coast command stop the
SLC.
[28] Freeze output
Freezes the output frequency of the
frequency converter.
[29] Start timer 0
Starts timer 0, see
for further description.
[30] Start timer 1
Starts timer 1, see
for further description.
[31] Start timer 2
Starts timer 2, see
for further description.
[32] Set digital out A
low
Any output with SL output A will be low.
[33] Set digital out B
low
Any output with SL output B will be low.
[34] Set digital out C
low
Any output with SL output Cwill be low.
[35] Set digital out
D low
Any output with SL output D will be low.
13-52 SL Controller Action
Array [20]
Option:
Function:
[36] Set digital out E
low
Any output with SL output E will be low.
[37] Set digital out F
low
Any output with SL output F will be low.
[38] Set digital out A
high
Any output with SL output A will be high.
[39] Set digital out B
high
Any output with SL output B will be high.
[40] Set digital out C
high
Any output with SL output C will be high.
[41] Set digital out
D high
Any output with SL output D will be
high.
[42] Set digital out E
high
Any output with SL output E will be high.
[43] Set digital out F
high
Any output with SL output Fwill be high.
[60] Reset Counter A Resets Counter A to zero.
[61] Reset Counter B Resets Counter B to zero.
[70] Start timer 3
Start Timer 3, see
for further description.
[71] Start timer 4
Start Timer 4, see
for further description.
[72] Start timer 5
Start Timer 5, see
for further description.
[73] Start timer 6
Start Timer 6, see
for further description.
[74] Start timer 7
Start Timer 7, see p
for further description.
Parameter Descriptions
Operating Instructions VLT
®
CDS302 and CDS303
96
MG34M302 - VLT
®