13-01 Start Event
Option:
Function:
[5]
Torque limit
The torque limit, set in
4-16 Torque
Limit Motor Mode
or
4-17 Torque Limit
Generator Mode
, has been exceeded.
[6]
Current limit
The motor current limit, set in
4-18 Current Limit
, has been
exceeded.
[7]
Out of current
range
The motor current is outside the
range set in
4-18 Current Limit
.
[8]
Below I low
The motor current is lower than set
in
4-50 Warning Current Low
.
[9]
Above I high
The motor current is higher than set
in
4-51 Warning Current High
.
[10]
Out of speed range The speed is outside the range set in
4-52 Warning Speed Low
and
.
[11]
Below speed low
The output speed is lower than the
setting in
4-52 Warning Speed Low
.
[12]
Above speed high
The output speed is higher than the
setting in
[13]
Out of feedb. range The feedback is outside the range set
in
4-56 Warning Feedback Low
and
4-57 Warning Feedback High
.
[14]
Below feedb. low
The feedback is below the limit set in
4-56 Warning Feedback Low
.
[15]
Above feedb. high
The feedback is above the limit set in
4-57 Warning Feedback High
.
[16]
Thermal warning
The thermal warning turns on when
the temperature exceeds the limit in
the motor, the frequency converter,
the brake resistor or the thermistor.
[17]
Mains out of range The mains voltage is outside the
specified voltage range.
[18]
Reversing
The output is high when the
frequency converter is running
counter clockwise (the logical
product of the status bits “running”
AND “reverse”).
[19]
Warning
A warning is active.
[20]
Alarm (trip)
A (trip) alarm is active.
[21]
Alarm (trip lock)
A (Trip lock) alarm is active.
[22]
Comparator 0
Use the result of comparator 0.
[23]
Comparator 1
Use the result of comparator 1.
[24]
Comparator 2
Use the result of comparator 2.
[25]
Comparator 3
Use the result of comparator 3.
[26]
Logic rule 0
Use the result of logic rule 0.
[27]
Logic rule 1
Use the result of logic rule 1.
13-01 Start Event
Option:
Function:
[28]
Logic rule 2
Use the result of logic rule 2.
[29]
Logic rule 3
Use the result of logic rule 3.
[33]
Digital input DI18
Use the result of digital input 18.
[34]
Digital input DI19
Use the result of digital input 19.
[35]
Digital input DI27
Use the result of digital input 27.
[36]
Digital input DI29
Use the result of digital input 29.
[37]
Digital input DI32
Use the result of digital input 32.
[38]
Digital input DI33
Use the result of digital input 33.
[39]
Start command
A start command is issued.
[40]
Drive stopped
A stop command (Jog, Stop, Qstop,
Coast) is issued – and not from the
SLC itself.
[41]
Reset Trip
A reset is issued
[42]
Auto-reset Trip
An Auto reset is performed.
[43]
Ok key
The [OK] key is pressed.
[44]
Reset key
The [Reset] key is pressed.
[45]
Left key
The [
◄
] key is pressed.
[46]
Right key
The [
►
] key is pressed.
[47]
Up key
The [
▲
] key is pressed.
[48]
Down key
The [
▼
] key is pressed.
[50]
Comparator 4
Use the result of comparator 4.
[51]
Comparator 5
Use the result of comparator 5.
[60]
Logic rule 4
Use the result of logic rule 4.
[61]
Logic rule 5
Use the result of logic rule 5.
[94]
RS Flipflop 0
[95]
RS Flipflop 1
[96]
RS Flipflop 2
[97]
RS Flipflop 3
[98]
RS Flipflop 4
[99]
RS Flipflop 5
[100] RS Flipflop 6
[101] RS Flipflop 7
13-02 Stop Event
Select the boolean (TRUE or FALSE) input to activate Smart Logic
Control.
Option:
Function:
[0]
*
False
For descriptions [0]-[61], see
Start Event
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current limit
Parameter Descriptions
Operating Instructions VLT
®
CDS302 and CDS303
MG34M302 - VLT
®
is a registered Danfoss trademark/Commercial Compressor
83