0-13 Readout: Linked Set-ups
Array [5]
Range:
Function:
0
*
[0 - 255 ] View a list of all the set-ups linked by means of
0-12 This Set-up Linked to
. The parameter has one
index for each parameter set-up. The parameter
value displayed for each index represents which
set-ups are linked to that parameter set-up.
Index
LCP value
0
{0}
1
{1,2}
2
{1,2}
3
{3}
4
{4}
Table 6.3 Example: Set-up 1 and Set-up 2 are
linked
0-14 Readout: Edit Set-ups / Channel
Range:
Function:
0
*
[-2147483648 -
2147483647 ]
View the setting of
for
each of the four different communication
channels. When the number is displayed in
hex, as it is in the LCP, each number
represents one channel.
Numbers 1-4 represent a set-up number;
‘F’ means factory setting; and ‘A’ means
active set-up. The channels are, from right
to left: LCP, FC-bus, USB, HPFB1-5.
Example: The number AAAAAA21h means
that the FC bus selected Set-up 2 in
, the LCP selected Set-up 1
and all others used the active set-up.
6.2.2 0-2* LCP Display
Define the display in the Graphical Logic Control Panel.
0-20 Display Line 1.1 Small
Option:
Function:
Select a variable for display
in line 1, left position.
[0]
None
[1501]
Running Hours
[1502]
kWh Counter
[1508]
Number of Starts
[1509]
Number of Resets
[1600]
Control Word
[1601]
Reference [Unit]
[1602]
Reference %
[1603]
Status Word
[1605]
Main Actual Value [%]
[1609]
Custom Readout
[1610]
Power [kW]
0-20 Display Line 1.1 Small
Option:
Function:
[1611]
Power [hp]
[1612]
Motor Voltage
[1613]
Frequency
[1614]
Motor Current
[1615]
Frequency [%]
[1616]
Torque
[1617]
*
Speed [RPM]
[1618 ] Motor Thermal
[1619 ] KTY sensor temperature
[1620 ] Motor Angle
[1622 ] Torque %
[1630]
DC Link Voltage
[1632 ] Brake Energy /s
[1633 ] Brake Energy /2 min
[1634]
Heatsink Temp.
[1635]
Inverter Thermal
[1636]
Inv. Nom. Current
[1637]
Inv. Max. Current
[1638]
SL Control State
[1639]
Control Card Temp
[1650]
External Reference
[1651 ] Pulse Reference
[1652]
Feedback [Unit]
[1653 ] Digi Pot Reference
[1654]
Feedback 1 [Unit]
[1655 ] Feedback 2 [Unit]
[1660]
Digital Input
[1661]
Terminal 53 Switch Setting
[1662]
Analog Input 53
[1663]
Terminal 54 Switch Setting
[1664]
Analog Input 54
[1665]
Analog Output 42 [mA]
[1666 ] Digital Output [bin]
[1667]
Freq. Input #29 [Hz]
[1668]
Freq. Input #33 [Hz]
[1669]
Pulse Output #27 [Hz]
[1670]
Pulse Output #29 [Hz]
[1671]
Relay Output [bin]
[1672]
Counter A
[1673]
Counter B
[1680 ] Fieldbus CTW 1
[1682 ] Fieldbus REF 1
[1684]
Comm. Option STW
[1685 ] FC Port CTW 1
[1686 ] FC Port REF 1
[1690 ] Alarm Word
[1691 ] Alarm Word 2
[1692 ] Warning Word
[1693 ] Warning Word 2
[1694]
Ext. Status Word
[2580]
Cascade Status
[2581 ] Compressor Status
Parameter Descriptions
Operating Instructions VLT
®
CDS302 and CDS303
48
MG34M302 - VLT
®
is a registered Danfoss trademark/Commercial Compressor
6
6