6.16.12 16-** Data Readouts
Par.
No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
16-0* General Status
16-00 Control Word
0 N/A
All set-ups
FALSE
0
V2
16-01 Reference [Unit]
0 ReferenceFeedbackUnit
All set-ups
FALSE
-3
Int32
16-02 Reference [%]
0 %
All set-ups
FALSE
-1
Int16
16-03 Status Word
0 N/A
All set-ups
FALSE
0
V2
16-05 Main Actual Value [%]
0 %
All set-ups
FALSE
-2
N2
16-09 Custom Readout
0 CustomReadoutUnit
All set-ups
FALSE
-2
Int32
16-1* Motor Status
16-10 Power [kW]
0 kW
All set-ups
FALSE
1
Int32
16-11 Power [hp]
0 hp
All set-ups
FALSE
-2
Int32
16-12 Motor Voltage
0 V
All set-ups
FALSE
-1
Uint16
16-13 Frequency
0 Hz
All set-ups
FALSE
-1
Uint16
16-14 Motor current
0 A
All set-ups
FALSE
-2
Int32
16-15 Frequency [%]
0 %
All set-ups
FALSE
-2
N2
16-16 Torque [Nm]
0 Nm
All set-ups
FALSE
-1
Int32
16-17 Speed [RPM]
0 RPM
All set-ups
FALSE
67
Int32
16-18 Motor Thermal
0 %
All set-ups
FALSE
0
Uint8
16-22 Torque [%]
0 %
All set-ups
FALSE
0
Int16
16-3* Drive Status
16-30 DC Link Voltage
0 V
All set-ups
FALSE
0
Uint16
16-32 Brake Energy /s
0 kW
All set-ups
FALSE
0
Uint32
16-33 Brake Energy /2 min
0 kW
All set-ups
FALSE
0
Uint32
16-34 Heatsink Temp.
0 °C
All set-ups
FALSE
100
Uint8
16-35 Inverter Thermal
0 %
All set-ups
FALSE
0
Uint8
16-36 Inv. Nom. Current
ExpressionLimit
All set-ups
FALSE
-2
Uint32
16-37 Inv. Max. Current
ExpressionLimit
All set-ups
FALSE
-2
Uint32
16-38 SL Controller State
0 N/A
All set-ups
FALSE
0
Uint8
16-39 Control Card Temp.
0 °C
All set-ups
FALSE
100
Uint8
16-40 Logging Buffer Full
[0] No
All set-ups
TRUE
-
Uint8
16-41 LCP Bottom Statusline
0 N/A
All set-ups
TRUE
0
VisStr[5
0]
16-5* Ref. & Feedb.
16-50 External Reference
0 N/A
All set-ups
FALSE
-1
Int16
16-52 Feedback[Unit]
0 ProcessCtrlUnit
All set-ups
FALSE
-3
Int32
16-53 Digi Pot Reference
0 N/A
All set-ups
FALSE
-2
Int16
16-54 Feedback 1 [Unit]
0 ProcessCtrlUnit
All set-ups
FALSE
-3
Int32
16-55 Feedback 2 [Unit]
0 ProcessCtrlUnit
All set-ups
FALSE
-3
Int32
16-56 Feedback 3 [Unit]
0 ProcessCtrlUnit
All set-ups
FALSE
-3
Int32
16-6* Inputs & Outputs
16-60 Digital Input
0 N/A
All set-ups
FALSE
0
Uint16
16-61 Terminal 53 Switch Setting
[0] Current
All set-ups
FALSE
-
Uint8
16-62 Analog Input 53
0 N/A
All set-ups
FALSE
-3
Int32
16-63 Terminal 54 Switch Setting
[0] Current
All set-ups
FALSE
-
Uint8
16-64 Analog Input 54
0 N/A
All set-ups
FALSE
-3
Int32
16-65 Analog Output 42 [mA]
0 N/A
All set-ups
FALSE
-3
Int16
16-66 Digital Output [bin]
0 N/A
All set-ups
FALSE
0
Int16
16-67 Pulse Input #29 [Hz]
0 N/A
All set-ups
FALSE
0
Int32
16-68 Pulse Input #33 [Hz]
0 N/A
All set-ups
FALSE
0
Int32
16-69 Pulse Output #27 [Hz]
0 N/A
All set-ups
FALSE
0
Int32
Parameter Descriptions
Operating Instructions VLT
®
CDS302 and CDS303
138