Pa
r. No.
#
Para
mete
r descripti
on
Def
ault value
4-
se
t-
up
Cha
nge
duri
ng
op
era
-
tio
n
Conve
r-
sion inde
x
Type
27-0
*
C
o
nt
ro
l &
S
ta
tus
27-
01
Pump Sta
tus
[0] Re
ad
y
All se
t-
up
s
TRU
E
-
U
in
t8
27-
02
M
anua
l P
ump
Contr
ol
[0
] N
o O
pe
rat
io
n
2 s
et-up
s
TRU
E
-
Ui
nt8
27-03
Current
Ru
nti
m
e H
ours
0 h
All se
t-
up
s
TRU
E
74
U
in
t3
2
27-
04
Pump
Tota
l Lifeti
me Ho
urs
0 h
All se
t-
up
s
TRU
E
74
Ui
nt32
27-1
*
Conf
igurat
ion
27-
10
Cascade
Contro
ller
[0]
Di
sab
led
2 s
et-up
s
FALSE
-
Ui
nt8
27-
11
Numb
er
O
f D
rive
s
1 N
/A
2 se
t-
up
s
FA
LS
E
0
U
in
t8
27-
12
Number Of
Pumps
SR
2 s
et-up
s
FALSE
0
Ui
nt8
27-
14
Pu
mp
Capaci
ty
100
%
2 s
et-
ups
FALSE
0
U
in
t16
27-
16
Ru
nt
im
e B
ala
nc
in
g
[0
]
Ba
lan
ce
d Pr
io
rit
y 1
2 s
et-up
s
TRU
E
-
Ui
nt8
27-
17
M
oto
r St
arters
[0
] Di
re
ct Onli
ne
2
se
t-
ups
FALSE
-
U
in
t8
27-
18
Spin
Tim
e for Unuse
d Pumps
SR
All se
t-
up
s
TRU
E
0
Ui
nt16
27-
19
Rese
t
Cur
rent Runt
ime H
ours
[0
]
Do
n
ot rese
t
All se
t-
up
s
TRU
E
-
Ui
nt8
2
7
-2*
Band
widt
h Setting
s
27-
20
Normal
O
pera
tin
g
Ran
ge
SR
All se
t-
up
s
TRU
E
0
U
in
t8
27-
21
Ove
rri
de Lim
it
100
%
All se
t-
up
s
TRU
E
0
Ui
nt8
27
-2
2
Fi
xe
d S
pe
ed On
ly O
per
at
in
g Ran
ge
SR
All se
t-
up
s
TRU
E
0
U
in
t8
27-
23
St
ag
in
g De
la
y
15 s
All se
t-
up
s
TRU
E
0
Ui
nt16
27-
24
De
stag
in
g De
lay
15 s
Al
l set-
up
s
TR
U
E
0
Ui
nt16
27-
25
Ove
rri
de Hold Tim
e
10 s
All se
t-
up
s
TRU
E
0
Ui
nt16
27-
27
Mi
n
Sp
ee
d Desta
ge De
lay
SR
All se
t-
up
s
TRU
E
0
Ui
nt16
27-3
*
St
agin
g
Spee
d
27-
30
Auto
Tune Sta
gi
ng Speeds
[1
] E
nab
le
d
All se
t-
up
s
TRU
E
-
U
in
t8
27-
31
Stage On Spe
ed
[RP
M
]
SR
All se
t-
up
s
TRU
E
67
Ui
nt16
27-
32
Stage
O
n S
pe
ed
[Hz]
SR
All se
t-
up
s
TRU
E
-1
U
in
t1
6
27-
33
Stage
Of
f Speed [RPM]
SR
All se
t-
up
s
TRU
E
67
Ui
nt16
27-
34
Stage
Of
f Spe
ed [Hz]
SR
All se
t-
up
s
TRU
E
-1
Ui
nt16
27-4
*
St
agin
g
Se
tt
in
gs
27-
40
Auto
Tune Sta
gi
ng Set
tin
gs
[0]
Di
sab
led
All se
t-
up
s
TRU
E
-
U
in
t8
27-
41
Ramp Down Delay
10
.0 s
All se
t-
up
s
TRU
E
-1
Ui
nt16
27-
42
R
amp
Up
De
lay
2.
0 s
All se
t-
up
s
TRU
E
-1
U
in
t1
6
27-
43
Stagi
ng T
hresho
ld
SR
All se
t-
up
s
TRU
E
0
Ui
nt8
27-
44
De
stag
in
g Thresho
ld
SR
All se
t-
up
s
TRU
E
0
U
in
t8
27-
45
Stagi
ng Spe
ed [R
PM]
0 R
PM
All se
t-
up
s
TRU
E
67
Ui
nt16
27-
46
Stagi
ng Sp
ee
d
[Hz]
0.
0 H
z
All
se
t-
up
s
TRU
E
-1
U
in
t1
6
27-
47
Desta
ging
Spee
d [RPM]
0 R
PM
All se
t-
up
s
TRU
E
67
Ui
nt16
27-
48
Desta
ging
Sp
eed
[
H
z]
0.
0 Hz
All se
t-
up
s
TRU
E
-1
Ui
nt16
2
7
-5*
Al
te
rn
ate
Se
tt
ing
s
27-
50
Automa
tic Al
te
rna
tio
n
[0]
Di
sab
led
All se
t-
up
s
FA
LS
E
-
U
in
t8
27-
51
Al
ternat
io
n Event
nu
ll
All se
t-
up
s
TRU
E
-
Ui
nt8
27-
52
Al
ternat
io
n Ti
me I
nte
rval
0 m
in
All se
t-
up
s
TRU
E
70
U
in
t1
6
27-
53
Al
te
rnat
io
n Ti
me
r Value
0 mi
n
All se
t-
up
s
TRU
E
70
Ui
nt16
27-
54
Al
ternat
io
n At Time
of Day
[0]
Di
sab
led
Al
l set-
up
s
TR
U
E
-
Ui
nt
8
27-
55
Al
te
rn
at
ion
Pr
ed
ef
in
ed
Tim
e
SR
All se
t-
up
s
TRU
E
0
TimeOfDay-
WoDa
te
27-
56
Al
ternat
e Cap
acity is <
0 %
All
se
t-
up
s
TRU
E
0
U
in
t8
27-
58
Run Next
Pu
mp Del
ay
0.1
s
All se
t-
up
s
TRU
E
-1
Ui
nt16
3.1.23
Cascade CTL
Opt
ion 27
-**
3 Parameter Lists
VLT
®
AQUA Drive Programming Guide
266
MG.20.O4.02 - VLT
®
is a registered Danfoss trademark
3