Pa
r. No.
#
Para
mete
r descripti
on
Def
ault value
4-
se
t-
up
Cha
nge
duri
ng
op
era
-
tio
n
Conve
r-
sion inde
x
Type
14-0
*
In
ve
rt
er
Swit
ch
in
g
14-
00
Switchi
ng Pa
ttern
nu
ll
All se
t-
up
s
TRU
E
-
U
in
t8
14-
01
Sw
itchi
ng
Freq
uency
nu
ll
All se
t-
up
s
TRU
E
-
Ui
nt8
14-
03
O
vermo
du
lat
io
n
[1
] O
n
All
se
t-
up
s
FA
LS
E
-
U
in
t8
14-
04
PWM Ra
ndom
[0
] O
ff
All se
t-
up
s
TRU
E
-
Ui
nt8
14-1
*
M
ain
s On
/Off
14-
10
Ma
in
s F
ai
lu
re
[0
] N
o fu
nc
tio
n
All se
t-
up
s
FALSE
-
Ui
nt8
14
-1
1
Ma
in
s Vo
lta
ge at
M
ain
s
Fa
ul
t
SR
All se
t-
up
s
TRU
E
0
U
in
t1
6
14-
12
Function a
t Ma
in
s Im
balance
[3] De
rat
e
All se
t-
up
s
TRU
E
-
Ui
nt8
14-2
*
Rese
t
Fu
n
ct
ion
s
14-
20
Rese
t Mode
[10]
Automa
tic reset
x
10
All se
t-
up
s
TRU
E
-
Ui
nt8
14-21
Automa
tic R
esta
rt Time
10 s
Al
l set-
up
s
TR
U
E
0
Ui
nt16
14-
22
Op
erat
ion
M
ode
[0] No
rmal
op
er
atio
n
All se
t-
up
s
TRU
E
-
Ui
nt8
14-
23
Typ
ecod
e Setting
nu
ll
2 se
t-
up
s
FA
LS
E
-
U
in
t8
14-
25
Trip Delay at
To
rque
Limit
60 s
All se
t-
up
s
TRU
E
0
Ui
nt8
14-
26
Tri
p De
lay at I
nverte
r Fault
SR
All se
t-
up
s
TRU
E
0
U
in
t8
14-
28
Producti
on
Se
ttings
[0]
No
actio
n
All se
t-
up
s
TRU
E
-
Ui
nt8
14-
29
Service Code
0 N
/A
All se
t-
up
s
TRU
E
0
In
t32
1
4
-3*
Cu
rre
nt
Li
m
it
Ctrl
.
14-
30
Current
Li
m
Ctrl,
P
roport
ion
al
Ga
in
100
%
All se
t-
up
s
FA
LS
E
0
U
in
t1
6
14-
31
Current
Lim
Ctrl
, Inte
gration
Time
0.
02
0 s
All se
t-
up
s
FALSE
-3
Ui
nt16
14-
32
Current
Lim
Ctrl
, Fi
lter Tim
e
27
.0
m
s
All se
t-
up
s
FALSE
-4
Ui
nt16
14-4
*
Ener
gy
Op
ti
misi
ng
14-
40
VT Le
vel
66 %
All se
t-
up
s
FA
LS
E
0
U
in
t8
14-
41
AEO Mini
mum
Magnetisation
SR
All se
t-
up
s
TRU
E
0
Ui
nt8
14-
42
M
inim
um
AE
O Fre
qu
ency
10
H
z
All
se
t-
up
s
TRU
E
0
U
in
t8
14-
43
M
otor Cosphi
SR
All se
t-
up
s
TRU
E
-2
Ui
nt16
14-5
*
Env
ir
o
nme
n
t
14-
50
RFI Fi
lte
r
[1] On
1 s
et-up
FALSE
-
Ui
nt8
14-
52
Fan Co
nt
ro
l
[0
] A
ut
o
All
se
t-
up
s
TRU
E
-
U
in
t8
14-
53
Fan Monitor
[1] Warn
in
g
All se
t-
up
s
TRU
E
-
Ui
nt8
14-
55
O
utp
ut Fil
ter
[0
] No
Fil
ter
1 s
et-up
FALSE
-
Ui
nt
8
14-
59
Act
ual
Numbe
r of
I
nvert
er U
nits
SR
1 s
et-up
FALSE
0
Ui
nt8
14-6
*
Aut
o
D
er
ate
14-
60
Function a
t Over Te
m
perat
ure
[1] De
rat
e
All se
t-
up
s
TRU
E
-
Ui
nt8
14-
61
Functio
n at I
nve
rter O
ve
rlo
ad
[1] De
rat
e
Al
l set-
up
s
TR
U
E
-
Ui
nt
8
14-
62
Inv.
Overloa
d De
rate
Current
95 %
All se
t-
up
s
TRU
E
0
Ui
nt16
14-8
*
Opti
ons
14-
80
O
pti
on Sup
pl
ie
d by
E
xterna
l 2
4VD
C
[0
] N
o
2 s
et-up
s
FALSE
-
Ui
nt8
3.1.13
Special Functions 14-**
VLT
®
AQUA Drive Programming Guide
3 Parameter Lists
MG.20.O4.02 - VLT
®
is a registered Danfoss trademark
251