CAN message
Priority
6
PGN
61184
XID
0x0FA2 (MSB first)
Occurrence
when required
Modes
operational, reduced, calibration
Sent by
configuration tool
Sent to
PVED-CL
Data field
Bytes
Encoding
Value/Range
Description
1, 2
UNSIGNED16
0x0FA2 (MSB first)
extended message identifier (XID)
3, 4
UNSIGNED16
(see parameter list)
parameter index
5 – 8
UNSIGNED32
(depends on a
parameter)
parameter value
SetParameterResponse
Sent back upon the SetParameter request and contains both parameter index and value. If, due to any
reason, parameter value has not been changed, the previous and still valid one is reported.
CAN message
Priority
6
PGN
61184
XID
0x0FA3 (MSB first)
Occurrence
upon request
Modes
operational, reduced, calibration
Sent by
PVED-CL
Sent to
configuration tool
Data field
Bytes
Encoding
Value/Range
Description
1, 2
UNSIGNED16
0x0FA3 (MSB first)
extended message identifier (XID)
3, 4
UNSIGNED16
(see parameter list)
parameter index
5 – 8
UNSIGNED32
(depends on a
parameter)
parameter value
RestoreDefaults
Used to set all parameter values to factory defaults.
Please note that the values are not stored in non-volatile memory unless CommitData command is sent.
CAN message
Priority
6
Technical Information
PVED-CL Communication Protocol, version 1.38 Technical Information