![background image](http://html1.mh-extra.com/html/danfoss/pved-cl/pved-cl_technical-information_4068739030.webp)
A typical successful valve auto-calibration message sequence:
MMI.StartValveAutoCalibration
→
PVED-CL
PVED-CL.ValveAutoCalibrationStatus.auto-calibration in progress
→
MMI
PVED-CL.ValveAutoCalibrationStatus.auto-calibration in progress
→
MMI
...
PVED-CL.ValveAutoCalibrationStatus.auto-calibration in progress
→
MMI
PVED-CL.SetParameterResponse.right dead-band value (index 738)
→
MMI
PVED-CL.ValveAutoCalibrationStatus.auto-calibration in progress
→
MMI
PVED-CL.SetParameterResponse.left dead-band value (index 737)
→
MMI
PVED-CL.ValveAutoCalibrationStatus.auto-calibration in progress
→
MMI
PVED-CL.SetParameterResponse.right maximum value (index 747)
→
MMI
PVED-CL.ValveAutoCalibrationStatus.auto-calibration in progress
→
MMI
PVED-CL.SetParameterResponse.left maximum value (index 729)
→
MMI
PVED-CL.CommitDataResponse.Commit operation has just begun
→
MMI
PVED-CL.ValveAutoCalibrationStatus.Commit process has started
→
MMI
PVED-CL.CommitDataResponse.Commit succeeded
→
MMI
PVED-CL.ValveAutoCalibrationStatus.auto-calibration completed
→
MMI
SelectProgram
Used for requesting the program change for a defined steering device.
CAN message
Priority
6
PGN
61184
XID
0x0FAE (MSB first)
Occurrence
when required
Modes
operational, reduced
Sent by
MMI
Sent to
PVED-CL
Data field
Bytes
Encoding
Value/Range
Description
1, 2
UNSIGNED16
0x0FAE (MSB first)
extended message identifier (XID)
3
UNSIGNED8
0 – 9
20 – 24
25 – 29
30 – 34
program number for:
– steering wheel
– high priority steering device
– low priority steering device
– high priority external set-point controller
Technical Information
PVED-CL Communication Protocol, version 1.38 Technical Information
Control
30
11079551 • Rev BA • July 2014