Data field (error identification data) (continued)
Bytes
Encoding
Value/Range
Description
6–7
UNSIGNED16
0 – 0xFFFE
0xFFFF
– error code
– wrong index or information not available
Data field (timestamp)
Bytes
Encoding
Value/Range
Description
1, 2
UNSIGNED16
0x0FB4 (MSB first)
extended message identifier (XID)
3
UNSIGNED8
1 – 16
buffer index (the oldest error at index 1)
4
UNSIGNED8
1
timestamp details
5–8
UNSIGNED32
0 – 0xFFFFFFFE
0xFFFFFFFF
timestamp:
– the value of a timer which starts counting upon
PVED-CL power-on, observed when the error
occurred
– wrong index or no information available
Data field (temperature)
Bytes
Encoding
Value/Range
Description
1, 2
UNSIGNED16
0x0FB4 (MSB first)
extended message identifier (XID)
3
UNSIGNED8
1 – 16
buffer index (the oldest error at index 1)
4
UNSIGNED8
2
temperature details
5–6
SIGNED16
-50 – 150
150 – 450
-32768
PVED temperature:
– temperature in oC, observed when the error
occurred
– temperature sensor provided data, but was likely
to be damaged by being oveheated
– wrong index or no information available
ClearErrorEntries
Used for clearing all error entries in the persistent error buffer.
CAN message
Priority
6
PGN
61184
XID
0x0FB5 (MSB first)
Occurrence
when needed
Modes
operational, reduced, calibration
Sent by
configuration tool
Sent to
PVED-CL
Data field
Bytes
Encoding
Value/Range
Description
1, 2
UNSIGNED16
0x0FB5 (MSB first)
extended message identifier (XID)
Technical Information
PVED-CL Communication Protocol, version 1.38 Technical Information
Diagnostics (proprietary)