CAN message (continued)
PGN
61184
XID
0x0FA4 (MSB first)
Occurrence
when required
Modes
operational, reduced, calibration
Sent by
configuration tool
Sent to
PVED-CL
Data field
Bytes
Encoding
Value/Range
Description
1, 2
UNSIGNED16
0x0FA4 (MSB first)
extended message identifier (XID)
3
UNSIGNED8
0x5C
check value
RestoreDefaultsResponse
Sent back to signal the status.
CAN message
Priority
6
PGN
61184
XID
0x0FA5 (MSB first)
Occurrence
upon request
Modes
operational, reduced, calibration
Sent by
PVED-CL
Sent to
configuration tool
Data field
Bytes
Encoding
Value/Range
Description
1, 2
UNSIGNED16
0x0FA5 (MSB first)
extended message identifier (XID)
3
UNSIGNED8
0x00
0x0FF
- restoring defaults failed
- all parameter values changed to factory
defaults
CommitData
This is a request for copying all modified parameters to non-volatile memory.
CAN message
Priority
6
PGN
61184
XID
0x0FA6 (MSB first)
Occurrence
when required
Modes
operational, reduced, calibration
Technical Information
PVED-CL Communication Protocol, version 1.38 Technical Information
Configuration
11079551 • Rev BA • July 2014
19