GetCurrentMode
Used to get the information about the current PVED-CL mode.
CAN message
Priority
6
PGN
61184
XID
0x0FA9 (MSB first)
Occurrence
when required
Modes
operational, reduced, calibration, fault
Sent by
configuration tool
Sent to
PVED-CL
Data field
Bytes
Encoding
Value/Range
Description
1, 2
UNSIGNED16
0x0FA9 (MSB first)
extended message identifier (XID)
GetCurrentModeResponse
Information about the current mode.
CAN message
Priority
6
PGN
61184
XID
0x0FAA (MSB first)
Occurrence
200 ms after claiming an address (if no address arbitration lost) and upon
request
Modes
operational, reduced, calibration, fault
Sent by
PVED-CL
Sent to
configuration tool
Data field
Bytes
Encoding
Value/Range
Description
1, 2
UNSIGNED16
0x0FAA (MSB first)
extended message identifier (XID)
3
UNSIGNED8
0x55
0x0AA
0x0AF
0x0FF
current mode:
– calibration
– operational
– reduced
– fault
StartStopStatus
This command is used to make PVED-CL start/stop sending status information. Power-on state: status
disabled.
Technical Information
PVED-CL Communication Protocol, version 1.38 Technical Information
Status
22
11079551 • Rev BA • July 2014