Data field (continued)
Bytes
Encoding
Value/Range
Description
3
SIGNED16
0x53
0x03
0x0A3
0x54
0x04
0x0A4
0x55
0x05
0x0A5
Command:
– arm high priority steering device enabling/
disabling
– enable high priority steering device
– disable high priority steering device
– arm low priority steering device enabling/disabling
– enable low priority steering device
– disable low priority steering device
– arm high priority external set-point con. enabling/
disabling
– enable high priority external set-point controller
– disable high priority external set-point controller.
DisableSteeringDevice Response
The message is transmitted upon the DisableSteeringDevice command to inform whether the
operation succeeded.
However, as DisableSteeringDevice command is ignored when the OSP is not present, in this case no
response will be sent back.
CAN message
Priority
6
PGN
61184
XID
0x0FB1 (MSB first)
Occurrence
upon request, on timeout
Mode
operational, reduced
Sent by
PVED-CL
Sent to
MMI
Data field
Bytes
Encoding
Value/Range
Description
1, 2
UNSIGNED16
0x0FB1 (MSB first)
extended message identifier (XID)
3
UNSIGNED8
0x00
0x03
0x53
0x0A3
0x0F3
High priority steering device status:
– device not mapped
– device enabled
– device enabled. Change armed
– device disabled
– device disabled. Change armed
4
UNSIGNED8
0x00
0x04
0x54
0x0A4
0x0F4
Low priority steering device status:
– device not mapped
– device enabled
– device enabled. Change armed
– device disabled
– device disabled. Change armed
5
UNSIGNED8
0x00
0x05
0x55
0x0A5
0x0F5
High priority external set-point controller:
– device not mapped
– device enabled
– device enabled. Change armed
– device disabled
– device disabled. Change armed
Technical Information
PVED-CL Communication Protocol, version 1.38 Technical Information
Control
32
11079551 • Rev BA • July 2014