GetErrorEntry
The command is used to retrieve the data stored in error buffers.
CAN message
Priority
3
PGN
61184
XID
0x0FB3 (MSB first)
Occurrence
when needed
Modes
operational, reduced, calibration and fault
Sent by
configuration tool
Sent to
PVED-CL
Data field
Bytes
Encoding
Value/Range
Description
1, 2
UNSIGNED16
0x0FB3 (MSB first)
extended message identifier (XID)
3
UNSIGNED8
1 – 16
buffer index (the oldest error at index 1)
4
UNSIGNED8
0
1
2
Request details
– error code
– timestamp when error occurred since power on
– PVED-CL PCB temperature when error occurred
GetErrorEntryResponse
The message presents data available in the error log.
CAN message
Priority
6
PGN
61184
XID
0x0FB4 (MSB first)
Occurrence
upon request
Modes
operational, reduced, calibration and fault
Sent by
PVED-CL
Sent to
configuration tool
Data field (error identification data)
Bytes
Encoding
Value/Range
Description
1, 2
UNSIGNED16
0x0FB4 (MSB first)
extended message identifier (XID)
3
UNSIGNED8
1 – 16
buffer index (the oldest error at index 1)
4
UNSIGNED8
0
error code details
5
UNSIGNED8
0
0x55
0xAA
0xFF
error severity:
– caution
– nominal
– critical
– wrong index or no information available
Technical Information
PVED-CL Communication Protocol, version 1.38 Technical Information
Diagnostics (proprietary)
11079551 • Rev BA • July 2014
35