TT11
HVIL
The HVIL is short for “High Voltage Interlock Loop”.
HVIL is a hardware signal, and its purpose is to
protect the user. When the system is fully installed
and connected, the HVIL internal loop is closed which
results in a short circuit between its two input pins.
The HVIL signal is used to open the high-voltage
battery contactor when its internal loop is opened
during product maintenance or repair (e.g. removal of
MCU cover or disconnection of high power connector)
thereby protecting the user.
Description
The troubleshooting tree 11 indicates a warning in
Operational state and an error in Standby state where
the HVIL current was greater than the maximum
allowed current. The possible causes of this error are
listed below, in order of likelihood:
1.
The HVIL parameters were not configured
correctly. To correct this, the user must
access the TM4 ODIN tool and go to the HVIL
parameters to set them according to the
needs and the limits set by the Operations
and Maintenance Guide.
2.
There is a problem with the HVIL power
source that is connected to the HVIL line. This
problem is external to the Motor Control Unit
(MCU), refer to HVIL source Troubleshooting
Guide.
3.
The MCU is defective. The system must be
turned OFF, and the MCU removed and
replaced.
Note:
Refer to the TM4 Product Operation and
maintenance guide for more details.
Note
: Refer to the TM4 Product installation guide for
more details on installation and deinstallation
procedure including safety warning considerations.
To correctly diagnose the faulty system, connect the
Diagnostic Tool (see «Diagnostics» section for test
equipment
and
descriptions)
and
follow
the
troubleshooting tree procedure below.
See “Safety Warnings” and “Troubleshooting Tips”
sections for general guidelines on system diagnostics.
System Mode
Referred by SysFile ID
Condition
Possible Causes
Standby or
Operational
0x0331 0x0332
HVIL over current
fault was detected.
1.
MCU HVIL parameters were not properly
configured.
2.
HVIL power source fault.
3.
Defective MCU.
Содержание SPICER TM4 SUMO HP HV Powertrain
Страница 1: ...1 Dana TM4 SUMO HP HV Powertrain Troubleshooting Guide SMTS 0603 March 2022 ...
Страница 9: ...9 General Information Dana TM4 Motor and MCU Components Example Dana TM4 Motor Dana TM4 MCU ...
Страница 14: ...14 General Information Motor connector head Identification Dana TM4 MCU A3 Dana TM4 Motor ...
Страница 36: ...36 Service Codes ...
Страница 38: ...38 Service Codes ...
Страница 41: ...41 Service Codes Connector type 2 pinout Connector type 1 pinout ...
Страница 47: ...47 Service Codes Connector type 2 pinout Connector type 1 pinout ...
Страница 51: ...51 Service Codes Motor internal resistance measurement table ...
Страница 52: ...52 Service Codes Connector Head Identification TM4 Motor connector Type 1 TM4 Motor connector Type 2 ...
Страница 53: ...53 Service Codes ...
Страница 54: ...54 Service Codes ...
Страница 55: ...55 Service Codes ...
Страница 57: ...57 Service Codes ...
Страница 62: ...62 Service Codes Connector type 2 pinout ...
Страница 63: ...63 Service Codes ...
Страница 64: ...64 Service Codes ...
Страница 67: ...67 Service Codes Connector type 2 pinout ...
Страница 68: ...68 Service Codes ...
Страница 69: ...69 Service Codes ...
Страница 71: ...71 Service Codes ...
Страница 72: ...72 Service Codes ...
Страница 73: ...73 Service Codes ...
Страница 76: ...76 Service Codes ...
Страница 77: ...77 Service Codes ...
Страница 79: ...79 Service Codes ...
Страница 85: ...85 Service Codes ...
Страница 87: ...87 Service Codes ...
Страница 89: ...89 Service Codes ...
Страница 91: ...91 Service Codes ...
Страница 105: ...105 Service Codes ...
Страница 107: ...107 Service Codes ...
Страница 109: ...109 Service Codes ...
Страница 111: ...111 Service Codes ...
Страница 113: ...113 Service Codes ...
Страница 115: ...115 Service Codes ...
Страница 117: ...117 Service Codes ...
Страница 122: ...122 Service Codes ...
Страница 125: ...125 Service Codes References ...
Страница 145: ...145 Service Codes ...
Страница 146: ...146 Service Codes ...
Страница 147: ...147 Service Codes ...
Страница 148: ...148 Service Codes ...
Страница 150: ...150 Service Codes ...
Страница 152: ...152 Service Codes ...
Страница 154: ...154 Service Codes Connector type 1 and type 2 pinouts Expected resistance measurement between CAN ports ...
Страница 158: ...158 Service Codes ...
Страница 160: ...160 Service Codes ...