56
CHAPTER SEVEN
AWS – WELD INSPECTION
7.1 Introduction to AWS
AWS
provides a toolkit for evaluating defects according to the American Welding
Society D1.1 welding code. The code offers inspectors a method to classify
discontinuities by calculating and Indication Rating (IR) using ultrasonics. This toolkit
can be used in conjunction with
TRIG
mode, outlined in the previous chapter, to
simultaneously display the sound path (SP), surface distance (SD), and depth (D).
The following sections provide an outline for using the
AWS
feature.
7.2 Additional Comments
Since the
DFX-7
is a gain controlled instrument, the following formula applies:
A – B – C = D
Where:
A = Discontinuity Indication Rating (DI)
B = Reference Indication Level (IL)
C = Attenuation Factor (AF); or 2(SP – 1)
SP = sound path in inches (2dB loss per inch of material thickness)
D = Indication Rating (IR)
Note:
all values are in dB.
Calibration Standards & Calibration:
In order to use the
AWS
feature, the operator must have calibration standards made
with the same size reflector at different distances within the testing range. The
standards should also be made of the same material type as the material to be
inspected.
AWS D1.1 Standard:
There are specific transducers that are required by the D1.1 standard. The
frequency specified by the standard is 2-2.5MHz. The user should refer to the
standard for further information.
7.3 Setup AWS
This section provides a step by step procedure to enable and setup the
AWS
feature.
Note:
A two point calibration should be done prior to proceeding. Refer to
Chapter
Five
for the calibration procedures. The
TRIG
mode will also be used for weld
Содержание DFX-7
Страница 2: ......
Страница 162: ...156 APPENDIX B SETUP LIBRARY Num Name Comment 1 Gn AGC Velocity 1 Enter Custom Name 2 3 4 5 6...