229
GB
(1) Wireless control devices for arming or disarming the hardwired system can only be used if the input for
hardwired control panel control has been connected.
(2) If the supply voltage drops below 10 V, the receiver issues a fault signal but continues to operate normally.
If the supply voltage drops below 8.5 V, all the alarm relay contacts switch to “open” status while the
status of the other relays remains the same.
Technical specifications Radio receiver for hardwired alarm
Identification and supervision • 32 detectors spread over 8 zones max.
• 4 control devices (keypads and remote controls) (1)
Power supply 12 V DC (from 9.5 to 15 V DC) (2)
Consumption 100 mA when at rest – 200 mA max.
With LCD back-lighting lit
Input/Output • 8 outputs for intrusion alarms (zones 1 to 8)
• 1 output for hardwired control panel arm/disarm control (1)
• 1 input for checking hardwired control panel
armed/disarmed status
• 1 output for the tamper alarm
• 1 output for faults
• 1 LED indicating power supply and fault status
Display 1 alphanumerical LCD screen (2 x 16-character lines)
2 function buttons and 1 internal audible vibrator
Radio link radio receiver module: compatible with Daitem range
(see Products compatible with receiver)
Menus • user/installer consultation
• installer guided programming
Test Mode reduced signal sensitivity (-10 dB) for installation checking
Tamper • protection against opening
• protection against removal
Degree of protection IP31 and IK04
Use indoor
Dimensions • box: 160 x 240 x 65 mm
• packaging: 330 x 185 x 75 mm
Weight 750 g
Operating temperature from -10 °C to + 55°C
To obtain advice when installing your system or before returning
equipment, please contact the Daitem technical support team
(see telephone number at the back of the alarm system installation
manual) or check the web site at:
www.daitem.co.uk
A team of qualified technicians will advise you what to do.
10. Technical data