212
GB
Fault relay operation is based on two parameters:
• break status (NC or NO),
• operating mode (MODE 1 or 2).
Whatever the break status (NC or NO), there are two different fault output
relay activation modes to manage system fault status:
• Repeat mode,
• Combined mode.
Example:
to change tamper relay operation so that the tamper alarm is also managed for radio
failure (NC, MODE2, RMSG_Y).
1.
Select the menu as shown below in order to identify the relay to be changed:
2.
The screen displays the current configuration. To change it, press the
OK
button. The screen
displays:
Tamper Output
NC (N.Closed)
*
3.
Press the
t
button 5 times and then
OK
. The screen displays:
Tamper Output
RMSG_Y
*
4.
Press
t
and then
OK
. The screen displays:
Tamper Output
>
NC MODE2 RMSG_Y
5.
Press
t
to continue and select menu exit.
Installing mode
>
Programming
Programming
>
Fault Ouput
IMPORTANT: the * character at the end of the line indicates the selected parameter in the
current configuration.
IMPORTANT: the fault output relay is factory-programmed for Combined Mode.
5.6 Fault (FLT) output relay operating modes
OK
Installing mode
>
Programming
t
Programming
>
Language select
t
t
OK
Programming
>
Recognition
Programming
>
Zone Outputs
Programming
>
Tamper Output
Tamper Output
>
NC MODE2 RMSG_N