200
GB
The installation menu has 4 sub-menus:
• Programming,
• Recognit. check,
• Erase,
• Test mode.
Press the receiver card “PROGRAM” button to access the installation menu.
The receiver exits the installation menu in the following cases:
• if the
“EXIT”
option is selected at the end of the installation menu,
- when the receiver box is closed and the tamper system activated,
- if the
t
and
OK
buttons are not pressed for 5 minutes.
3.3 Dip switches for parameter selection
3.4 Accessing the installation menu
(1) Using the receiver in tamper disabled mode means it is no longer compliant with IEC 79-2
Book 2.
IMPORTANT: the menu can only be accessed if the receiver box is open and if DIP1-1 (see
previous page) is positioned so as to disable the tamper system.
IMPORTANT: the receiver has 6 different languages and the factory-programmed language is
English. The first operation to be performed is to select the language.
IMPORTANT: do not forget that, as well as the DIP1-2 settings, the armed input operating
mode (ARS) requires the parameters in the “arm input” menu to be suitably configured (see
page 218).
DIP1-2
Arm input operation (ARS)
Input designed for positive voltage operation (factory setting)
Input designed for negative voltage operation
DIP1-1
Tamper protection against
opening/removal
Tamper control
enabled
(factory setting)
Tamper control
disabled
(1)
Installing mode
>
Programming
Installing mode
>
Recognit. check
Installing mode
>
Erase
Installing mode
>
Test mode